Need FREE Initial Consultation?

Electro Winning Wastewater Treatment Systems

Electro Winning Water Treatment Technology

Electro Winning Water Treatment technology has been in use in wastewater treatment application for decades. It utilizes a reticulated cathodes and special coded anodes to plate metals from wastewater. This technology is quite effective in a Sludgeless application, combined with Ion Exchange System, where the regenerant from the regeneration process with high concentration of metal can be treated with the electrowinning system to eliminate sludge.

Modified version of this technology has application in oxidizing Heavy Metals, BOD, COD, as well as destroying Cyanide and Ammonia from industrial wastewater streams.
Call SRI and discuss your application.

Waste Water Neutralization Calculations_U S

1. Caustic Addition – (pH is too low and must be raised)
Instructions: Enter values in blue boxes. Spreadsheet calculates values in yellow boxes
Inputs
Calculations

gmp

WW Flow Rate, Qww =

gal/day

Moles/L of OH needed =

moles/L

Incoming pH, pHin =

NaOH rate needed =

moles/day

Desired pH, pHout =

Caustic solution rate =

lb/day

Caustic sol’n % NaOH =

Caustic solution rate =

gal/day

Caustic sol’n density, ρ =

lb/gal

Daily cost of caustic =

$/day

Caustic solution cost =

$/lb

Wastewater Neutralization Calculations – U.S. units
1. Caustic Addition – (pH is too low and must be raised)
Instructions: Enter values in blue boxes. Spreadsheet calculates values in yellow boxes
Inputs

gmp

WW Flow Rate, Qww =

gal/day

Incoming pH, pHin =

Desired pH, pHout =

Caustic sol’n % NaOH =

Caustic sol’n density, ρ =

lb/gal

Caustic solution cost =

$/lb

Calculations

Moles/L of OH needed =

moles/L

NaOH rate needed =

moles/day

Caustic solution rate =

lb/day

Caustic solution rate =

gal/day

Daily cost of caustic =

$/day

Wastewater Neutralization Calculations – U.S. units
2. Acid Addition – (pH is too high and must be lowered)
Instructions: Enter values in blue boxes. Spreadsheet calculates values in yellow boxes
Inputs
Calculations

gmp

WW Flow Rate, Qww =

gal/day

Moles/L of H+ needed =

moles/L

Incoming pH, pHin =

H2SO4 rate needed =

moles/day

Desired pH, pHout =

Acid solution rate =

lb/day

Acid sol’n % H2SO4 =

Acid solution rate =

gal/day

Acid sol’n density, ρ =

lb/gal

Daily cost of acid =

$/day

Acid solution cost =

$/lb

Wastewater Neutralization Calculations – U.S. units
2. Acid Addition – (pH is too high and must be lowered)
Instructions: Enter values in blue boxes. Spreadsheet calculates values in yellow boxes
Inputs

gmp

WW Flow Rate, Qww =

gal/day

Incoming pH, pHin =

Desired pH, pHout =

Acid sol’n % H2SO4 =

Acid sol’n density, ρ =

lb/gal

Acid solution cost =

$/lb

Calculations

Moles/L of H+ needed =

moles/L

H2SO4 rate needed =

moles/day

Acid solution rate =

lb/day

Acid solution rate =

gal/day

Daily cost of acid =

$/day