The purpose of the Emergency Response Contingency Plan (ERCP) is to establish a process to respond to emergency cases during the business operation. This plan would include, but not limited to the following action plans:

SRI can provide training, plan and dry run practices to your employees and ERT personnel, which can minimize environmental impact while reducing risks to the Company’s personnel and assets.

Waste Water Neutralization Calculations_U S

1. Caustic Addition – (pH is too low and must be raised)
Instructions: Enter values in blue boxes. Spreadsheet calculates values in yellow boxes
Inputs
Calculations

gmp

WW Flow Rate, Qww =

gal/day

Moles/L of OH needed =

moles/L

Incoming pH, pHin =

NaOH rate needed =

moles/day

Desired pH, pHout =

Caustic solution rate =

lb/day

Caustic sol’n % NaOH =

Caustic solution rate =

gal/day

Caustic sol’n density, ρ =

lb/gal

Daily cost of caustic =

$/day

Caustic solution cost =

$/lb

Wastewater Neutralization Calculations – U.S. units
1. Caustic Addition – (pH is too low and must be raised)
Instructions: Enter values in blue boxes. Spreadsheet calculates values in yellow boxes
Inputs

gmp

WW Flow Rate, Qww =

gal/day

Incoming pH, pHin =

Desired pH, pHout =

Caustic sol’n % NaOH =

Caustic sol’n density, ρ =

lb/gal

Caustic solution cost =

$/lb

Calculations

Moles/L of OH needed =

moles/L

NaOH rate needed =

moles/day

Caustic solution rate =

lb/day

Caustic solution rate =

gal/day

Daily cost of caustic =

$/day

Wastewater Neutralization Calculations – U.S. units
2. Acid Addition – (pH is too high and must be lowered)
Instructions: Enter values in blue boxes. Spreadsheet calculates values in yellow boxes
Inputs
Calculations

gmp

WW Flow Rate, Qww =

gal/day

Moles/L of H+ needed =

moles/L

Incoming pH, pHin =

H2SO4 rate needed =

moles/day

Desired pH, pHout =

Acid solution rate =

lb/day

Acid sol’n % H2SO4 =

Acid solution rate =

gal/day

Acid sol’n density, ρ =

lb/gal

Daily cost of acid =

$/day

Acid solution cost =

$/lb

Wastewater Neutralization Calculations – U.S. units
2. Acid Addition – (pH is too high and must be lowered)
Instructions: Enter values in blue boxes. Spreadsheet calculates values in yellow boxes
Inputs

gmp

WW Flow Rate, Qww =

gal/day

Incoming pH, pHin =

Desired pH, pHout =

Acid sol’n % H2SO4 =

Acid sol’n density, ρ =

lb/gal

Acid solution cost =

$/lb

Calculations

Moles/L of H+ needed =

moles/L

H2SO4 rate needed =

moles/day

Acid solution rate =

lb/day

Acid solution rate =

gal/day

Daily cost of acid =

$/day